(i) The operator or manager of the processing establishment must take
all necessary steps to ensure that the raw milk is treated (within 36
hours of acceptance), if the milk is kept at a temperature not exceeding
60C, or within 48 hours of acceptance it the milk is kept at a temperature
of 40C or lower.
which complies with the standards, laid down in Annex A.
(iii) Heat-treated milk must meet the following requirements:
(a) pasteurized milk must comply with Clause 2(a) of this Annex.
(b) UHT milk must have been obtained by the treatment as defined under
the item on definition and shall comply with the requirements given therein.
2. MILK PROCESSING
Prior to processing, raw milk shall be filtered or clarified to remove
visible dirt and any other foreign material in it. The milk may be homogenized
before pasteurization at appropriate pressure.
After completion of the day’s run the part of the homogenizer shall be
dismantled and thoroughly washed with detergent solution followed by rinsing
with hot water. Before using fresh batch of milk, the homogenizer shall
be sterilized by pumping through it hot water or chlorine solution. The
piston packing and leather gaskets of the homogeniser when worn out, shall
be replaced as early as possible.
(a) Pasteurisation:
The milk shall be heated to at least 660C and held at 660(2 continuously
for at least 30 minutes, or it shall be heated to at least 740C and held
at 740C continuously for at least 15 seconds in a standard and properly
operated equipment. Other temperature and time combjnations that enable
the pasteurised milk to meet the hygienic requirements may also be adopted
after approval by competent authority. To ensure that the bacteria present
in the foam are killed, space heaters should be provided. The clear positioning
and accuracy of the indicating and recording thermo meters shall be checked
regularly. The long stemindicating thermometer shall be accurate within
+O.50C. The recording thermometer shall be accurate within +10C between
63 and 640C for holder pasteurization and within 10C and between 71 and
720C for high temperature short time (1-ITST) pasteurization.
After holding the milk, it should be cooled immediately in the standard
and properly operated equipment to a temperature not exceeding SOC. The
pasteurized milk should be maintained at a temperature not exceeding 7C
until it leaves the milk plant for distribution.
All parts of the pasteurizer should be kept in a hygienic condition. Appropriate
type of detergentsanitizers which do not adversely affect the quality
of milk should be used for effective cleanliness and sterility of the
pasteurization plant. The rubber gaskets of the pasteurizer need special
attention in regard to cleaning operations because of the deposition of
milk residues. All possible precautions shall be taken to avoid recontamination
of raw milk after pasteurization through improperly designed or leaky
equipment pumps, dirty bottles and bottling equipment, contaminated water,
dust flies and from dirty habits of dairy plant personnel.
Pasteurized milk shall be filled in suitable package of standard quality.
The package shall be so shaped as to permit effective cleaning operation.
The package should not have inaccessible corners where milk deposits or
scales are likely to accumulate or difficult to clean. The returned empty
package shall be appropriately cleaned and sanitised using suitable detergent
and sanitizer.
(1) Laboratory Control
The control dairy laboratory plays a vital role in checking the efficiency
of milk processing. A well-equipped laboratory with competent quality
control staff is essential for an efficient operation of milk processing
plant. Depending upon the quantity of milk handled by each dairy, appropriate
layout plant may be formulated.
(c)
Milk Products
All the milk products manufactured in the processing plants should conform
to the hygienic requirements outlined above. ‘Wherever applicable the
milk products should also conform to the national/international standards.
|